A true metamorphosis of the human living environment into a new space that pursues superiority, comfort, cleanliness, health and symbiosis.
The limited enhancement of the living environment can hardly meet the needs of contemporary fast-developing life and hinders the pursuit of contemporary people's individuality and fashion in the family province.
Living only reaches a lower limit to meet the basic needs of "living".
At present, China is in the construction of the project to solve the water leakage. Phenomena such as dampness and mold. Usually use grouting. Installation of dehumidifiers and ventilation fans, etc., these methods can temporarily solve the building's waterproofing problems but can not permanently and completely solve the problem.
Electric infiltration system is the most advanced technology in the world today to prevent seepage and moisture and mold, the technology has been maturely applied for more than twenty years. It is mainly used in underground projects, tunnel's. Reservoirs. The field of impermeability in projects such as power stations. And in Korea, Europe. Taiwan and other important projects have been achieved, has proved its excellent anti-seepage anti-lake and anti-mildew ability.
Years of application
Application Areas
Area of distribution
Leakage and mold is a common problem in many homes in the later stages of use, which not only affects the aesthetics of the house, but also brings a lot of inconvenience to people's daily lives. Leakage and mold is not a problem that will immediately appear, so it often does not raise enough attention in the decoration stage. Once leakage occurs, it will be very tedious to deal with. What are the main hazards of house leakage?
Food poisoning
Moldy food, when consumed, can directly cause poisoning.
Mold infection
After the human body is infected with mold, the mold will directly reproduce in the human body, causing a variety of diseases, such as mycobacterial pneumonia, which can lead to pulmonary fibrosis.
Mold allergy
Mold can cause a variety of allergic diseases, such as bronchial asthma, nausea, vomiting, dermatitis and intestinal diseases.
At present, the traditional high-pressure chemical grouting repair method is usually used to solve the water leakage problem in engineering, which is only a temporary or temporary leak plugging method with high recurrence frequency and unstable anti-seepage effect, and cannot permanently and completely solve the water leakage problem. At the same time, due to repeated grouting repair (too many holes in the structure), the strength of the concrete structure is reduced, resulting in side effects and thus affecting the service life of the structure.
Therefore, the ordinary damp-proof technology and damp-proof system cannot meet the requirements of similar structure functions, so an alternative technology was born.
Principle of impermeable dehumidification system A
It is based on the principle of electric osmosis, the control device of the system generates a series of low-voltage pulse electric charge, which acts on the water molecules in the capillaries and gaps inside the structure through the electromagnetic field composed of positive and negative electrodes, ionizing them, and the ionized water molecules move in the direction of the negative electrodes installed on the outside of the structure, thus causing the water inside the structure to drain away and gradually become dry, as long as As long as the system keeps working, the water will keep moving toward the outside of the structure and will not backflow into the inside of the structure again and keep the structure in a permanent dry state, and at the same time, prevent the water on the outside of the structure from entering the inside.
Experiments have shown that the force of water molecules moving inside the structure after ionization is much greater than the gravity of water, and in practical applications, the system can successfully prevent the infiltration of pressure water at a head of nearly 600 meters (such as the Tonstad hydroelectric power plant shaft and turbine room plugging treatment in Norway).
The technology breaks the traditional waterproofing concept, "water for water", according to the advanced principle of electric penetration, through a series of low-voltage multi-pulse positive and negative charge work and the development of a new anti-seepage moisture and mold technology, it can completely and permanently structure to solve the problem of water seepage moisture and mold.
Through close cooperation between architects and scientists, we invented the cross-genre technology of electric permeation and dehumidification in the early 1980s.
This technology is now widely used in many prestigious projects in Europe and has been well received and approved by our clients.
Intelligent operation, active impermeability B
After the system opens and runs, it detects the wall humidity data in real time, and when the wall humidity reaches the set limit, the system opens the anti-permeation dehumidification mode.
Active impermeability, dehumidification
No dead spots for impermeability and uniform coverage over the whole area.
One click on, fully automatic operation
Safe operation, using home power
Energy efficient, the average daily power consumption is between 0.2 and 2 degrees
Auto-on protection mode
01. The minimum distance between the anode titanium wire and the rebar ask shall not be less than 13mm ;
02. the length of the missing line of the circuit formed by each da line between 50m - 150m shall not exceed a maximum length of 150m.
03. Cathodes shall be installed before backfilling the earthwork